NOTE: The K2Pro is factory preset with a 90° arc setting,

and includes a pre-installed #2.5 nozzle.

CHANGING A NOZZLE

1. Loosen The Nozzle Retention Screw

Use your K-key (A) or a medium flat blade screw driver to loosen the Nozzle Retention

Screw (B) by turning counter-clockwise until it is no longer in front of the nozzle.

2. Accessing The Nozzle

The K2 Pro has a Flow Control (D) that when turned all the way counterclockwise to

"Off" will allow you to change nozzles with the water on. The riser will be popped up

with no water coming out. Or, to access the nozzle with water off, insert the K-key (A)

in the Pull Up Slot (F) on the top of the nozzle turret and turn the key 1/4 turn to insure

that the key does not slip out of the Pull Up Slot (F) when you pull it up. Firmly pull up

the entire spring-loaded Riser (L) to access the Nozzle Socket (H). Hold the riser

assembly up with one hand.

3. Removing The Nozzle

Insert the K-key (A) into the slot directly beneath the Nozzle Prongs (G) and push the

key to one side while pulling the nozzle out at the same time.

4. Installing A Nozzle

Press the desired nozzle into the Nozzle Socket (H) at a slight downward angle until

fully seated with the Nozzle Prongs (G) facing up up. The nozzle can be rotated with

the K-key (A) by inserting it into the pull out slot and using it to turn the nozzle into

place. Tighten the Nozzle Retention Screw (B) until the screw is flush with the top of

the head. NOTE: The Nozzle Retention Screw (B) when turned further clockwise while

the head is in operation will break up the straight stream and "fan it out" to provide

fallout of droplets for close in coverage around the head.

NOZZLE TURRET TOP

NOZZLE TURRET TOP

C

A

B

KEY

A

NOZZLE

KEY

B

RETENTION

NOZZLE

SCREW

RETENTION

SCREW

D

DISTANCE

D

AND FLOW

DISTANCE

CONTROL

AND FLOW

CONTROL

E

ARC SET

E

ADJUSTMENT

ARC SET

ADJUSTMENT

F

PULL UP SLOT

F

STANDARD NOZZLE PERFORMANCE DATA

Nozzle

Pressure Radius Flow

Precip in/hr

PSI

Ft.

GPM

n

#1.0

30

30

1.2

0.21 0.25

40

31

1.3

0.23 0.27

50

31

1.5

0.27 0.31

60

32

1.8

0.32 0.37

#1.5

30

36

1.5

0.22 0.26

40

37

1.8

0.25 0.29

50

37

2.0

0.28 0.32

60

38

2.2

0.29 0.34

#2.0

30

35

1.8

0.28 0.33

40

35

2.2

0.35 0.40

50

36

2.6

0.39 0.45

60

38

2.9

0.39 0.45

#2.5

30

37

2.5

0.35 0.41

40

38

3.0

0.40 0.46

Pre-

50

40

3.4

0.41 0.47

installed

60

40

3.8

0.46 0.53

3.0

30

36

3.0

0.45 0.51

40

37

3.4

0.48 0.55

50

38

4.0

0.53 0.62

60

41

4.4

0.50 0.58

ARC SELECTION:

ARC SELECTION:

40° to 360°

40° to 360°

NOZZLE ARROW

C

NOZZLE ARROW

PULL UP SLOT

Nozzle

Pressure Radius Flow

s

PSI

Ft.

#4.0

30

37

40

39

50

39

60

40

#5.0

30

37

40

38

50

41

60

43

#6.0

30

40

40

41

50

42

60

44

#8.0

30

38

40

44

50

45

60

46

*All precipitation rates calculated for 180° operation.

For the precipitation rate for a 360° sprinkler, divide by 2.

SETTING ARC ADJUSTMENT WITH WATER OFF OR ON

1. Finding The Left Start Position

Using the palm of your hand, twist the Nozzle Turret (K) all the way to the right,

then all the way to the left until it stops. Notice the position of the Nozzle Arrow (C).

This is the Fixed Left Start Position (M). The sprinkler will begin spraying from this

position and rotate clockwise until it reaches its Right Adjustable Stop (N).

2. Changing The Left Start Position

Insert tip of the K-key (A) into the Pull Up Slot (F) and turn ¼ turn to prevent the

key from slipping out. Then, firmly pull up the entire spring loaded riser assembly,

trying not to accidentally turn the Nozzle Turret (K). To change the Fixed Left Start

Position (M), turn the Lower Riser (L) any direction necessary to aim the Nozzle

Arrow (C) to the desired left start position. There is plastic ratchet at the base of

the riser and a "clicking" sound will be made while turning. The top Nozzle Turret (K)

section of the riser is not what is turned to adjust the left stop. However, it manually

turned to make sure the Nozzle Arrow (C) is all the way to the left fixed side.

3. Changing The Right Stop Position

Insert the K-key (A) or medium flat blade screwdriver into the Arc Set Adjustment (E)

slot. Turn clockwise to make the arc larger and counterclockwise to make the arc

smaller. The arrow at the end of the Arc Adjustment slot will point at the degrees of a

circle the head is set to rotate – indicated by the 360, 90 and 180 printed on the top of

the head. When set to full circle/360° rotation, the head will turn clockwise continuously.

4. Using The Distance And Flow Control

Insert K-key (A) or a medium flat screwdriver into the Distance and Flow Control (D)

with the water on. The distance/flow will be reduced as the Flow Control is turned

counterclockwise. When turned all the way counterclockwise, the head will be

turned "OFF". The riser will still pop up when the system is in operation with no

water coming out of the nozzle. The Nozzle Retention Screw (B) above the nozzle

can also be turned to break up the stream.

G

NOZZLE

PRONGS

H

NOZZLE

SOCKET

I

THE ARC'S

ADJUSTABLE

HOUSING

THE ARC'S

RANGE

CAN

ADJUSTABLE

RANGE

LOW ANGLE NOZZLES

Precip in/hr

Nozzle

Pressure Radius Flow

GPM

PSI

n

s

4.0

0.56 0.65

#1.0

30

4.5

0.57 0.66

40

5.2

0.66 0.76

50

5.6

0.67 0.78

60

4.8

0.68 0.78

#1.5

30

5.6

0.75 0.86

40

6.5

0.74 0.86

50

7.2

0.75 0.87

60

6.0

0.72 0.83

#2.0

30

6.8

0.78 0.90

40

7.5

0.82 0.95

50

8.4

0.84 0.96

60

7.9

1.05 1.22

#3.0

30

9.2

0.92 1.06

40

10.4

0.99 1.14

50

11.1

1.01 1.17

60

Setting Instructions

G

J

NOZZLE

KEY IN

J

PRONGS

KEYHOLE

KEY IN

KEYHOLE

K

NOZZLE

K

TURRET

NOZZLE

H

TURRET

L

NOZZLE

LOWER

L

SOCKET

RISER

LOWER

RISER

I

HOUSING

CAN

Precip in/hr

Ft.

GPM

n

s

26

1.1

0.31 0.36

30

1.3

0.28 0.32

30

1.4

0.30 0.35

30

1.6

0.34 0.40

27

1.4

0.37 0.43

28

1.7

0.42 0.48

31

1.9

0.38 0.44

30

2.1

0.45 0.52

30

2.1

0.45 0.52

31

2.4

0.48 0.56

33

2.8

0.50 0.57

31

3.1

0.62 0.72

32

3.0

0.56 0.65

34

3.5

0.58 0.67

35

3.9

0.61 0.71

35

4.3

0.68 0.78

N

RIGHT

ADJUSTABLE

N

RIGHT

STOP

ADJUSTABLE

STOP

M

LEFT

M

FIXED

LEFT

START

FIXED

START

K-RAIN MANUFACTURING CORP.

1640 Australian Avenue

Riviera Beach, FL 33404 USA

PH: 1-561-844-1002 / 1-800-735-7246

FAX: 1-561-842-9493

www.krain.com

© K-RAIN Manufacturing Corp.

Part Number: 11005115

Rev. 13

K-RAIN K2PRO SETTING INSTRUCTIONS Pdf Download (2024)

References

Top Articles
Latest Posts
Article information

Author: Kelle Weber

Last Updated:

Views: 6056

Rating: 4.2 / 5 (53 voted)

Reviews: 84% of readers found this page helpful

Author information

Name: Kelle Weber

Birthday: 2000-08-05

Address: 6796 Juan Square, Markfort, MN 58988

Phone: +8215934114615

Job: Hospitality Director

Hobby: tabletop games, Foreign language learning, Leather crafting, Horseback riding, Swimming, Knapping, Handball

Introduction: My name is Kelle Weber, I am a magnificent, enchanting, fair, joyous, light, determined, joyous person who loves writing and wants to share my knowledge and understanding with you.